BTU Meter (Thermal Meter)

btu-meter-U3000

A BTU (British Thermal Unit) Meter can be called with several different names which are Thermal meters, Thermal Flow meters, Ultrasonic Flow Meters, In-line flow Meters and Simply BTU Meters etc.

A regular BTU meter consists of two sensors that can measure temperature on the go. It is also backed by a flow measurement sensor and an energy calculator based on micro-processing technology. Sounds interesting right? But what is a BTU meter and how does it stand relevant to our day to day lives? What are the purposes that it serves in general and how modern-day industries are making use of the particular in their business-oriented needs? Here’s a complete guide to them all, do continue with your reading task to know more.

Our Team

All of us at Eagles Crew have a passion to deliver fantastic results through best quality workmanship and within the client budget. We combine the technical experience, best team to execute the job at its best quality.

Our Mission

Delivering what we promise, when we promise it! We believe in exceeding our clients’ expectations and consistently achieving excellence through our agility, innovation and best practices. Our commitment to support and add value for our customers, drives everything we do.

Our Portfolio

What is a BTU Meter?

To simply put what is BTU meter, the answer will be this. BTU meter stands for British Thermal Unit Meter. A BTU meter uses flow meters in conjunction with sensing devices to calculate energy usage in any fluid heating/cooling system.

BTU meters are also known as energy meters. In general, a BTU energy meter is used to charge customers for energy use. On the other hand, industries do utilise the same to monitor the effectiveness of emission measures or the decrease in productivity within the system, which influences the overall income. At times, BTU meters are used to measure the accurate thermal energy of refrigerated water consumption. Thus, it is also referred to as a thermal energy meter.

Other than the names discussed so far, a BTU meter is also known as a chilled water energy meter. It is because this device can read the heat conduction of chilled water. Till now as we have noticed, there are a variety of names and use cases that a BTU Meter has to serve while in the market. Now it’s time to dive deep into other necessary details and gain proper knowledge about the types, benefits and industry-specific benefits it has to serve.

BTU Meter – Type

For commoners, when dealing with what is a BTU meter? It is primarily used to measure the thermal energy expenditure of heating and cooling devices for commercial and residential buildings. There are different types of BTU meters available in the market. These types include the BTU flow meter, chilled water energy meter, thermal energy meter, ultrasonic flow meter and inline flow meter. Let’s have a detailed look at them.

Chilled Water Energy Meter

Thinking about what is BTU meter for chilled water? A chilled water energy meter is a BTU meter type that can appropriately measure the heating or cooling conditions under differential thermal consumption.

Thermal Energy Meter

The thermal energy meter monitors the level of liquid fed into the system, as well as the temperature differential between the entry and outflow. This data is then utilised to compute the total energy use during a specified time. Thermal energy meters can be put in individual cabinets for each housing unit or at the thermal power station.

Ultrasonic Flow Meters

The ultrasonic flow meter is a BTU Meter type that uses ultrasound to compute flow rate by measuring the velocity of the water. It is ideal for wastewater solutions but will not function with drinking or distilling water. As a consequence, this flow meter type is ideal for applications serving low maintenance, chemical compatibility and low-pressure losses.

Inline Flow Meters

The inline or in-line flow meter consists of a flow cell that is permanently mounted in a process line. This meter version has a built-in flow conditioner, improving the overall gas flow pattern. One advantage of in-line meters is that they do not demand as much of a continuous run as the other flow meters.

How does BTU Meter work?

For people living in the Middle-east, a top-quality and accurate meter system is a necessity. And to provide positive and trusted results, BTU meters are the best-suited option that one can opt for. Now, the real question is how BTU meter works? BTU meters are not a recent innovation. It has been present and running for years now.

These smart meters are capable of monitoring the thermal content of a flowing fluid in BTUs (British Thermal Units), making them extremely handy for residential complexes. As are used in air-conditioning systems. Therefore, it is also known as a chilled water BTU meter. Rather than calculating the entire building’s energy consumption, these meters measure the energy consumed by any liquid heating or cooling system. A BTU meter in chilled water system helps measure the thermal content present within.

BTU meter function is very simple. The main unit, temperature probes/sensors and the flow meter are the three key elements present within. When water flows through the pipeline, the flow meter measures the immediate flow rate using the Heat Exchange Principle of Thermodynamics and transmits this information to the primary unit. Likewise, the temperature sensor will detect and transmit the values of the comeback and supply pipes. Overall, these computations provide the real thermal consumption of each suite. The meter then adds up the cooling or heating use and sends it to the computer, which can then be accessed and billed accordingly.

BTU Metering Uses

BTU metering or thermal metering is widely used in commercial and residential buildings. It accurately measures the excess heat of cooling water usage in BTU (British Thermal Units), which is a fundamental measurement of thermal energy for residential and commercial buildings. The BTU (British Thermal Unit) Metering allows property owners to collect monthly cooling and heating expenses for an individual device that otherwise cannot be captured by regular electrical sensors. Thermal energy meters can capture thermal energy, maintaining a pleasant temperature.

Advanced BTU metering systems can monitor hydronic circulation rates and temperature differences over the whole HVAC unit (in suit). This computation calculates the real thermal expenditure of each suite.

BTU Meter – Importance and Benefits

The costs of disregarding temperature precision in BTU energy measurement might be more than anticipated. Inaccuracy arises when bad processes and equipment are employed in the system, resulting in the loss of thousands of dollars each year. By taking notes of the small details, this waste may be prevented. For example, the temperature sensors in the heat energy system have to be a perfect pair, or else uncertainties might quickly rise depending on the device’s efficiency levels. Regardless of how large or small the BTU measuring system is, it is crucial to understand that thermocouples are a critical component of the system and must be properly bought, deployed and maintained from time to time. Sometimes, it is considered straightforward to monitor and manage the temperature of the liquids and air that serve the structure. Nonetheless, it takes skill and effort.

If you are designing the plan for a new building or retrofitting a pre-existing construction using BTU measuring machines, it will be extremely advantageous for every building owner or landlord to calculate multiple utilities and recuperate the exact cost, avoiding the responsibility being passed on to the residing individuals and ultimately making them environmentally aware. Also, it will result in lower power usage, lowering costs for both tenants and landlords.

A BTU meter for ahu is extremely advantageous. It helps both residential and commercial buildings to keep a check on energy expenditure. Also, to check the current consumption of air-conditioners or heaters, one can use a BTU meter for chilled water or heating conditions to measure the thermal energy consumed within. BTU Meters can be used in Power Systems to track and implement energy-saving initiatives. Furthermore, these meters can measure the amount of heat energy used by a certain unit to keep the temperature stable. BTU metering solutions provide extended savings, as well as, an enhanced property value, making it an excellent investment. As per reports, thermal metering solutions have saved yearly $600 per suite, with a 20% decrease in yearly usage for measuring units in both renovation and modern building projects.

BTU Meter Installation Process

If you are planning to install BTU meters for residential or commercial sites, check out the points discussed below for complete details. Most companies offer BTU meters with installation guides. Often companies like Eagle Crew LLC provide dedicated engineers and professionals to customers. Thus helping them with the installation part. As we already know, a BTU meter, often known as a flow meter, is a device that can measure the thermal energy consumption of a heating or cooling system.

A BTU meter installation usually takes place either inline or as ultrasonic. These devices can be installed both vertically or horizontally, through the pipelines of the heating or cooling systems in concern. The Chip Hole must be oriented downward. To avoid incorrect results, test equipment should be put into ‘reset’ regularly.

In general, Flow meters are maintained on a routine basis in industrial settings to ensure that the detected measurements are correct. Thus allowing activities to operate in a safe, secure and reliable way.

BTU Meter and Eagles Crew LLC

There are a plethora of electronics companies that provide thermal energy meters. Among them, you can rely on us at Eagles Crew and search across a variety of BTU meter types as per convenience. That includes a thermal meter, Ultrasonic flow meter, thermal flow meter, as well an in-line flow meter. Our company also has an efficient team that promises to deliver positive results through world-class workmanship within the customer’s budget.

The dedicated service team helps with BTU meter installation as well as designing tero-fitting thermal meters. These installations are done either inline or ultrasonic, in general. Moreover, we at Eagles Crew also try and cater to BTU submetering requirements. The company and its engineers work collectively to offer regular maintenance and related services all along. Also, the team has developed certain skills concerning BTU metering that are of great use.

Eagle Crew’s supplied and installed BTU meters are certified under an electromagnetic flow meter, a flow transmitter and a couple of temperature sensors. Furthermore, the company provides BTU submetering solutions to commercial and residential buildings alike. Besides BTU meters, you can also check out our website to avail of services like energy meters, water meters and MEP works.

BTU Meter – Frequently Asked Questions (FAQs)

7000 BTUs, in general, are required to keep a 300 sq ft room comfortable and warm. For a 1000 sq ft room, the BTU level rises to 18,000.

The mathematical formula for the particular goes as BTU/Hr is equal to lbs multiplied by Delta T. Here, Delta T stands for the temperature difference “prior to” and “after” the procedure. Water mass in lbs stands as 1. And, BTU/Hr is also 1 (considered a flame)

Basically, the flow meter is a part of the entire BTU meter working principle. While the flow meter is in charge of measuring the flow rate of the liquid, the BTU meter takes care of both flow rate and return rate, simultaneously.

When talking about a chilled water system, a BTU meter in general is positioned within chilled water return lines, towards the direction of flow. Either in horizontal or in vertical position.

Check out the following steps. Do place the main meter following the flow meter under test > Make comparisons between the readings of the flow meter and the master flow meter, through a measured liquid volume > Calibrate the results of the flow meter and the master flow meter under test.

As BTUs are used to measure the energy utilised while removing heat from a room. Thus, the more BTU an AC will have the better purpose it serves to cool down a large space. Which is good.